Required Fields
Clear Form

Althon Swale Inlet Headwall-150

The Althon 150mm Swale Inlet Headwall is a swale and pond fibre reinforced precast concrete open inlet allowing surface water runoff to enter SUDS features, or to act as an outlet or overflow. This swale inlet is designed for pipework up to and including 150mm.

Max Concrete Pipe Size = 150mm
Max Plastic / Clayware Pipe Size = 150mm

Althon Swale Inlet Headwall-225

The Althon 225mm Swale Inlet Headwall is a swale and pond fibre reinforced precast concrete open inlet allowing surface water runoff to enter SUDS features, or to act as an outlet or overflow. This swale inlet is designed for pipework up to and including 225mm.

Max Concrete Pipe Size = 225mm
Max Plastic / Clayware Pipe Size = 225mm

Althon Swale Inlet Headwall-300

The Althon 300mm Swale Inlet Headwall is a swale and pond fibre reinforced precast concrete open inlet allowing surface water runoff to enter SUDS features, or to act as an outlet or overflow. This swale inlet is designed for pipework up to and including 300mm.

Max Concrete Pipe Size = 300mm
Max Plastic / Clayware Pipe Size = 300mm

R7C A Headwall

The R7CA precast headwall is an ideal headwall option for highways applications. R7CA headwall for highways has a backwall height of 750mm external and is suitable for pipework up to and including 225mm ID.

Max Plastic / Clayware Pipe Size = 225mm

H3C Headwall

The Althon H3C Headwall is a precast concrete headwall to suit plastic or clay pipes up to 300mm and concrete pipes up to 225mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories.

Max Concrete Pipe Size = 225mm
Max Plastic / Clayware Pipe Size = 300mm

R7C B Headwall

The R7CB precast headwall is an ideal headwall option for highways applications. R7CB headwall for highways has a backwall height of 880mm external and is suitable for pipework up to and including 300mm ID Concrete and 400mm ID Twinwall.

Max Concrete Pipe Size = 300mm
Max Plastic / Clayware Pipe Size = 400mm

H4C Headwall

Our H4C Headwall is a precast concrete headwall to suit plastic or clay pipes up to 300mm and concrete pipes up to 225mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories. The H4C has an integral toe 600mm from the underside of the headwall. 

Max Concrete Pipe Size = 225mm
Max Plastic / Clayware Pipe Size = 300mm

SP11 E Headwall

SP11E precast headwalls are produced with a horizontal wing walls at the front of the apron. SP11E precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP11E precast headwalls have been designed to suit plastic, clay or concrete pipework up to 300mm and have a backwall height of 850mm with a flat spillway. Althon SP11E precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 300mm
Max Plastic / Clayware Pipe Size = 300mm

R7C C Headwall

The R7CC precast headwall is an ideal headwall option for highways applications. R7CC headwall for highways has a backwall height of 1150mm external and is suitable for pipework up to and including 450mm ID Concrete and 500mm ID Twinwall.

Max Concrete Pipe Size = 450mm
Max Plastic / Clayware Pipe Size = 500mm

SP16 E Headwall

SP16E precast headwalls are produced with a horizontal wing walls at the front of the apron. SP16E precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP16E precast headwall has been designed to suit plastic or clay pipework up to 600mm and concrete pipework up to 675mm ID. It has a backwall height of 1350mm and a flat spillway. Althon SP16E precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 600mm

SP21 E Headwall

SP21E precast headwalls are produced with a horizontal wing walls at the front of the apron. SP21E precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP21E precast headwall has been designed to suit plastic or clay pipework up to 600mm and concrete pipework up to 675mm ID. It has a backwall height of 1350mm and a flat spillway. Althon SP21E precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 600mm

SP28 E Headwall

SP28E precast headwalls are produced with a horizontal wing walls at the front of the apron. SP28E precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP28E precast headwall has been designed to suit plastic or clay pipework up to 600mm and concrete pipework up to 675mm ID. It has a backwall height of 1350mm and a flat spillway. Althon SP28E precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 600mm

SP11 F Headwall

SP11F precast headwalls are produced with a horizontal wing walls at the front of the apron. SP11F precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP11F precast headwall has been designed to suit plastic or clay pipework up to 500mm and concrete pipework up to 450mm ID. It has a backwall height of 1090mm and a flat spillway. Althon SP11F precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 450mm
Max Plastic / Clayware Pipe Size = 500mm

H6C A Headwall

H6C A Headwalls are precast concrete headwalls to suit plastic or clay pipes up to 600mm and concrete pipes up to 450mm. H6C A Headwalls have a backwall height of 1100mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories.

Max Concrete Pipe Size = 450mm
Max Plastic / Clayware Pipe Size = 600mm

SP16 F Headwall

SP16F precast headwalls are produced with a horizontal wing walls at the front of the apron. SP16F precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP16F precast headwall has been designed to suit plastic or clay pipework up to 1050mm and concrete pipework up to 900mm ID. It has a backwall height of 1700mm and a flat spillway. Althon SP16F precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 900mm
Max Plastic / Clayware Pipe Size = 1050mm

Free headwall design service

If you cannot find what you are looking for our Free Headwall Design Service can help.

More information