SP16 H Headwall

SP16H precast headwalls are produced with a horizontal wing walls at the front of the apron. SP16H precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP16H precast headwall has been designed to suit plastic or clay pipework up to 1200mm and concrete pipework up to 1050mm ID. It has a backwall height of 2050mm and a flat spillway. Althon SP16H precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1200mm

SP10 E Headwall

Althon SP10E precast headwalls have horizontal wing walls at the front of the apron. SP10E precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 300mm
Max Plastic / Clayware Pipe Size = 300mm

SP10 F Headwall

Althon SP10F precast headwalls have wing walls 590mm high at the front of the apron. SP10F precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 450mm
Max Plastic / Clayware Pipe Size = 500mm

SP10 G Headwall

Althon SP10G precast headwalls have horizontal wing walls at the front of the apron. SP10G precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 450mm
Max Plastic / Clayware Pipe Size = 500mm

SP10 H Headwall

Althon SP10H precast headwalls have wing walls 540mm high at the front of the apron. SP10H precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 600mm

SP10 I Headwall

Althon SP10I precast headwalls have wing walls 780mm high at the front of the apron. SP10I precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 600mm

SP10 J Headwall

Althon SP10J precast headwalls have horizontal wing walls at the front of the apron. SP10J precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 600mm

SP10 K Headwall

Althon SP10K precast headwalls have wing walls 640mm high at the front of the apron. SP10K precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 750mm

SP11 I Headwall

SP11I precast headwalls are produced with a horizontal wing walls at the front of the apron. SP11I precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP11I precast headwall has been designed to suit plastic or clay pipework up to 600mm and concrete pipework up to 600mm ID. It has a backwall height of 1280mm and a flat spillway. Althon SP11I precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 600mm
Max Plastic / Clayware Pipe Size = 600mm

H10C A Headwall

H10C A Headwalls are precast concrete headwalls to suit plastic or clay pipes up to 750mm and concrete pipes up to 750mm. H10C A Headwalls have a backwall height of 1250mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories.

Max Concrete Pipe Size = 750mm
Max Plastic / Clayware Pipe Size = 750mm

SP16 I Headwall

SP16I precast headwalls are produced with a horizontal wing walls at the front of the apron. SP16I precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP16I precast headwall has been designed to suit plastic or clay pipework up to 1200mm and concrete pipework up to 1050mm ID. It has a backwall height of 2050mm and a flat spillway. Althon SP16I precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1200mm

SP21 H Headwall

SP21H precast headwalls are produced with a horizontal wing walls at the front of the apron. SP21H precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP21H precast headwall has been designed to suit plastic or clay pipework up to 1200mm and concrete pipework up to 1350mm ID. It has a backwall height of 2050mm and a flat spillway. Althon SP21H precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1350mm
Max Plastic / Clayware Pipe Size = 1200mm

SP28 H Headwall

SP28H precast headwalls are produced with a horizontal wing walls at the front of the apron. SP28H precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP28H precast headwall has been designed to suit plastic or clay pipework up to 1500mm and concrete pipework up to 1350mm ID. It has a backwall height of 2050mm and a flat spillway. Althon SP28H precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1350mm
Max Plastic / Clayware Pipe Size = 1500mm

H10C B Headwall

H10C B Headwalls are precast concrete headwalls to suit plastic or clay pipes up to 900mm and concrete pipes up to 900mm. H10C B Headwalls have a backwall height of 1650mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories.

Max Concrete Pipe Size = 900mm
Max Plastic / Clayware Pipe Size = 900mm

H10C C Headwall

H10C C Headwalls are precast concrete headwalls to suit plastic or clay pipes up to 900mm and concrete pipes up to 900mm. H10C C Headwalls have a backwall height of 2130mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories.

Max Concrete Pipe Size = 900mm
Max Plastic / Clayware Pipe Size = 900mm