Required Fields
Clear Form

H20C E Headwall

Althon H20C E Headwalls are two piece precast concrete headwall structures with rebated joints to be assembled on site around the drainage pipe, locked together by stainless steel cast-in sockets and brackets. H20C E Headwalls suit plastic or clay pipes up to 1050mm and concrete pipes up to 1050mm.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1050mm

H20C F Headwall

Althon H20C F Headwalls are two piece precast concrete headwall structures with rebated joints to be assembled on site around the drainage pipe, locked together by stainless steel cast-in sockets and brackets. H20C F Headwalls suit plastic or clay pipes up to 1650mm and concrete pipes up to 1500mm.

Max Concrete Pipe Size = 1500mm
Max Plastic / Clayware Pipe Size = 1650mm

H20C G Headwall

Althon H20C G Headwalls are two piece precast concrete headwall structures with rebated joints to be assembled on site around the drainage pipe, locked together by stainless steel cast-in sockets and brackets. H20C G Headwalls suit plastic or clay pipes up to 750mm and concrete pipes up to 750mm.

Max Concrete Pipe Size = 750mm
Max Plastic / Clayware Pipe Size = 750mm

H20C H Headwall

Althon H20C H Headwalls are two piece precast concrete headwall structures with rebated joints to be assembled on site around the drainage pipe, locked together by stainless steel cast-in sockets and brackets. H20C H Headwalls suit plastic or clay pipes up to 1050mm and concrete pipes up to 1050mm.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1050mm

H20C I Headwall

Althon H20C I Headwalls are two piece precast concrete headwall structures with rebated joints to be assembled on site around the drainage pipe, locked together by stainless steel cast-in sockets and brackets. H20C I Headwalls suit plastic or clay pipes up to 1650mm and concrete pipes up to 1500mm.

Max Concrete Pipe Size = 1500mm
Max Plastic / Clayware Pipe Size = 1650mm

SP11 M Headwall

SP11M precast headwalls are produced with a horizontal wing walls at the front of the apron. SP11M precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP11M precast headwall has been designed to suit plastic or clay pipework up to 750mm and concrete pipework up to 675mm ID. It has a backwall height of 1570mm and a flat spillway. Althon SP11M precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 750mm

SP15 J Headwall

Althon SP15J precast headwalls have horizontal wing walls at the front of the apron. SP15J precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1200mm

SP16 M Headwall

SP16M precast headwalls are produced with a horizontal wing walls at the front of the apron. SP16M precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP16M precast headwall has been designed to suit plastic or clay pipework up to 1200mm and concrete pipework up to 1050mm ID. It has a backwall height of 2400mm and a flat spillway. Althon SP16M precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1200mm

SP21 L Headwall

SP21L precast headwalls are produced with a horizontal wing walls at the front of the apron. SP21L precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP21L precast headwall has been designed to suit plastic or clay pipework up to 1500mm and concrete pipework up to 1500mm ID. It has a backwall height of 2400mm and a flat spillway. Althon SP21L precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1500mm
Max Plastic / Clayware Pipe Size = 1500mm

H20C J Headwall

H20C J Headwalls are two piece precast concrete headwall structures with rebated joints to be assembled on site around the drainage pipe and locked together by means of stainless steel cast-in sockets and brackets. H20C J Headwalls suit plastic or clay pipes up to 1650mm and concrete pipes up to 1500mm.

Max Concrete Pipe Size = 1500mm
Max Plastic / Clayware Pipe Size = 1650mm

SP28 L Headwall

SP28L precast headwalls are produced with a horizontal wing walls at the front of the apron. SP28L precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP28L precast headwall has been designed to suit plastic or clay pipework up to 1500mm and concrete pipework up to 1500mm ID. It has a backwall height of 2400mm and a flat spillway. Althon SP28L precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1600mm
Max Plastic / Clayware Pipe Size = 1800mm

H3C Penstock Headwall

Althon H3C Penstock Headwall is a one-piece reinforced concrete headwall that is factory fitted with penstocks up to 400mm. Stainless steel sockets are cast into the headwall for the penstock so the headwall does not have to be drilled on site.

Max Plastic / Clayware Pipe Size = 300mm

SP11 N Headwall

SP11N precast headwalls are produced with a horizontal wing walls at the front of the apron. SP11N precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP11N precast headwall has been designed to suit plastic or clay pipework up to 750mm and concrete pipework up to 675mm ID. It has a backwall height of 1570mm and a flat spillway. Althon SP11N precast concrete headwalls are cast to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 675mm
Max Plastic / Clayware Pipe Size = 750mm

SP15 K Headwall

Althon SP15K precast headwalls have wing walls 700mm high at the front of the apron. SP15K precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to a flap valve, duck bill valve, stop logs or weir wall.

Max Concrete Pipe Size = 1050mm
Max Plastic / Clayware Pipe Size = 1200mm

SP21 M Headwall

SP21M precast headwalls are produced with a horizontal wing walls at the front of the apron. SP21M precast headwalls are for inlets or outlets situated in locations with high or steep embankments or where the structure is required to provide protection to an accessory such as a flap valve, duck bill valve, stop logs or weir wall. SP21M precast headwall has been designed to suit plastic or clay pipework up to 1500mm and concrete pipework up to 1500mm ID. It has a backwall height of 2400mm and a flat spillway. Althon SP21M precast concrete headwalls are cast in two pieces and to suit the diameter and type of pipe being used and can be provided with fixings cast in at the time of manufacture to accommodate gratings, trash screens, flap valves, ladders, guardrails and flow and depth monitoring equipment.

Max Concrete Pipe Size = 1500mm
Max Plastic / Clayware Pipe Size = 1500mm

Free headwall design service

If you cannot find what you are looking for our Free Headwall Design Service can help.

More information