Download Datasheets

H8C A Headwalls are precast concrete headwalls to suit plastic or clay pipes up to 600mm and concrete pipes up to 450mm. H8C A Headwalls have a backwall height of 1150mm. Stainless steel sockets can be cast into the headwall for the attachment of gratings and other factory fitted accessories.

H8C A Headwalls are cast 150mm thick to provide a longer design life and greater cover to reinforcement.

We cast the opening in the back wall of our precast concrete headwalls to suit the pipe diameter and material of the pipe being used. We can cast multiple pipe openings, elliptical, square or rectangular culvert openings into any of our headwalls. We can also cast pipe openings into the wing walls of our headwalls. 

The H8C A Headwall weighs 1975kg

If you require any assistance or more information please contact us by phone on 01603 488700 or by email sales@althon.co.uk

H8C A Headwall line drawing
As standard our headwalls have a natural concrete finish.
We can offer coloured headwalls in 4 colours but the final shade is affected by many influences.
Our Headwall Products are available in a range of colours
Natural
Our Headwall Products are available in a range of colours
Cotswold
Our Headwall Products are available in a range of colours
Agate
Our Headwall Products are available in a range of colours
Raven Grey
Our Headwall Products are available in a range of colours
Everglade
Product Name
Max Pipe Opening PCC
Max Pipe Opening Plastic / C'ware
Backwall Height
Approx Headwall Weight (kg)
H8C A Headwall
450
600
1150
1975

Filters for H8C A Headwall Downloads. To Download CAD and PDF Files Please Register or Login

    All Available Downloads for H8C A Headwall - Page 4 of 4

    You can select multiple files below to be added to a single zip file, your selections will be retained across different Headwalls

    Title
    PDF
    CAD
    Add to Zip File

    H8C A Headwall + 150mm Penstock

    H8C A Headwall + 150mm Penstock + Cranked Grating

    H8C A Headwall + 150mm Penstock + 3 Sided Kee Klamp

    H8C A Headwall + 150mm Penstock + 3 Sided Kee Klamp + Cranked Grating

    H8C A Headwall + 150mm Penstock + Backwall Kee Klamp

    H8C A Headwall + 150mm Penstock + Backwall Kee Klamp + Cranked Grating

    H8C A Headwall + 250mm Penstock

    H8C A Headwall + 250mm Penstock + Cranked Grating

    H8C A Headwall + 250mm Penstock + 3 Sided Kee Klamp

    H8C A Headwall + 250mm Penstock + 3 Sided Kee Klamp + Cranked Grating

    H8C A Headwall + 250mm Penstock + Backwall Kee Klamp

    H8C A Headwall + 250mm Penstock + Backwall Kee Klamp + Cranked Grating

    H8C A Headwall + 300mm Penstock

    H8C A Headwall + 300mm Penstock + Cranked Grating

    H8C A Headwall + 300mm Penstock + 3 Sided Kee Klamp

    H8C A Headwall + 300mm Penstock + 3 Sided Kee Klamp + Cranked Grating

    H8C A Headwall + 300mm Penstock + Backwall Kee Klamp

    H8C A Headwall + 300mm Penstock + Backwall Kee Klamp + Cranked Grating

    H8C A Headwall + 400mm Penstock

    H8C A Headwall + 400mm Penstock + Cranked Grating

    H8C A Headwall + 400mm Penstock + 3 Sided Kee Klamp

    H8C A Headwall + 400mm Penstock + 3 Sided Kee Klamp + Cranked Grating

    H8C A Headwall + 400mm Penstock + Backwall Kee Klamp

    H8C A Headwall + 400mm Penstock + Backwall Kee Klamp + Cranked Grating

     

    BIM Objects

    If you cannot find what you are looking for, please either email us or use our Headwall Design Service

    You can select multiple files below to be added to a single zip file, your selections will be retained across different Headwalls

    H8C A Headwall - 300mm ID pipe - 100mm Invert Level

    Example Render

    H8C A Headwall - 300mm ID pipe - 100mm Invert Level render

    RFA Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download RFA Object

    ADSK Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download ADSK Object

    IFC Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download IFC Object

    COBie Parameters

    Parameter Name Parameter Value
    NamePrecastConcreteHeadwall_H8CA_300mmIDPipe_100mmIL_AlthonLimited
    CreatedBydrawings@althon.co.uk
    CreatedOn2019-04-17T09:17:00
    Categoryn/a
    DescriptionPrecast Concrete Headwall
    AssetTypeFixed
    Manufacturersales@althon.co.uk
    ModelNumberH8CA
    WarrantyGuarantorPartssales@althon.co.uk
    WarrantyDurationPartsn/a
    WarrantyGuarantorLaborn/a
    WarrantyDurationLaborn/a
    WarrantyDurationUnityear
    ReplacementCostn/a
    ExpectedLife>100
    DurationUnityear
    WarrantyDescriptionn/a
    NominalLength1370
    NominalWidth685
    NominalHeight1150
    ModelReferencePrecast Concrete Headwall
    Shapen/a
    Size1370 x 685 x 1150
    ColourLight Grey
    FinishSteel mould concrete finish
    Graden/a
    MaterialConcrete
    Constituentsn/a
    FeaturesLifting points cast into headwall
    AccessibilityPerformancen/a
    CodePerformanceBS EN 15258:2008
    SustainabilityPerformancen/a

    Althon_General Parameters

    Parameter Name Parameter Value
    AuthorAlthon Limited
    BIMObjectNameAlthonLimited_PrecastConcreteHeadwall_H8CA_300mmIDPipe_100mmIL
    Version1
    LastUpdated2019-04-17T09:17:00
    ADSKCompatible2X3
    RevitCompatible2018 +
    ManufactureNameAlthon Limited
    ManufacturerURLwww.althon.co.uk
    NBSDescriptionPrecast concrete headwall unit
    NBSNoten/a
    NBSOfficeMasterTagn/a
    NBSReference45-25-40/305
    NBSTypeIDn/a
    DocumentationLiteraturehttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationInstallationGuidehttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationTechnicalhttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationCertificatesOn request
    Uniclass2015codePr_20_93_37_65
    Uniclass2015TitlePrecast concrete headwall units
    Uniclass2015VersionProducts v1.13
    AlthonGeneralNotesWe can cast multiple pipe opening, elliptical, square or rectangular culvert openings into any of our headwalls. We can also cast pipe openings into the wing walls of our headwalls.
    AlthonHeadwallInstallationUnits should be bedded on minimum 150mm of semi-dry concrete. Sit the headwall level or with a slight fall 1:50 from pipe to spill mouth.
    AlthonHandlingA. Weight of concrete is based on 2.4 tonne/m³+5% is recommended for sizing lifting equipment B. All lifting points shall be used as specified below - Anchor points & loops - Total Qty 3 C. Unit to be lifted as per lifting diagram
    AlthonConcreteA. Mix ref: Self-compacting DC4/DS4 Mix B. Lifting strength bases on 2 cubes = 20N/mm² C. Characteristic 28 day cube strength = 50N/mm² D. Concrete provides Design Chemical Class 4 (DC4) to special Digest1, Table F2
    AlthonReinforcementA. Reinforcement to BS EN 13369 B. Scheduling, dimensioning, bending & cutting to BS8666 C. Cage to be machine tied with steel wire
    AlthonManufactureA. Manufacture to BS EN 15258:2008 precast concrete products - Retaining wall elements, Factory Production Control certificate number: 0086-CPR-650448 & BS EN 13369 B. Tolerances to BS EN 13369 clause 4.3.1.1 C. Finishing Top: Class A Sides: Class A Base: Class A Rear of back wall: Self-Levelled D. Marking: Units shall be indelibly marked to show: mould reference code De-mould date Job reference number and unique product number unit weight (kg)
    AlthonDesignA. Concrete design to EC2 B. Althon have designed the concrete units only, the site conditions should be assessed for suitability by the scheme designer C. Units are designed to withstand a vertical live load surcharge of 10kN/M² D. Weight of soil - 18kN/M² E. Angle of internal friction = 30 Deg. F. Design Life: >100 years Cover Block Size (mm): All Faces 55 Min Cover Size (mm): All Faces 55 Max Cover Size (mm): All Faces 60 Exposure induced by Carbonation: All Faces XC3/4 Corrosion induced by Chloride: XD3 Freeze/thaw attack: XF4 Chemical attack: XA3
    AlthonFabricationA. Manufacture IAW EN 1090-2 EXC CLASS 1 B. Material grade is to be: BS EN 10025 S275 C. Welding carried out IAW EN 1090-2 PARA 7.5.4 - 7.5.18 D. All fillet and butt welds to have a minimum throat thickness of 6mm & joints to be fully welded where possible. E. Ensure vertical flats are fully welded both sides where possible. F. All sharp edges and burrs are to be removed. G. Remove all weld splatter. H. Holes by punching are permitted with reaming. I. Galvanising is carried out after fabrication to BS EN:ISO 1461
    AlthonSpecificationInformationOpening in back wall cast to suit outside diameter of the pipe work. Invert level of pipe can be set to your specification
    AlthonHeadwallMaxPipeSizeMax Pipe Opening PCC = 450mm ID and Max Pipe Opening Pastic/Clayware = 600mm ID

    Built with: Autodesk Inventor Professional 2018

    H8C A Headwall - 375mm ID pipe - 100mm Invert Level

    Example Render

    H8C A Headwall - 375mm ID pipe - 100mm Invert Level render

    RFA Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download RFA Object

    ADSK Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download ADSK Object

    IFC Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download IFC Object

    COBie Parameters

    Parameter Name Parameter Value
    NamePrecastConcreteHeadwall_H8CA_375mmIDPipe_100mmIL_AlthonLimited
    CreatedBydrawings@althon.co.uk
    CreatedOn2019-04-17T09:17:00
    Categoryn/a
    DescriptionPrecast Concrete Headwall
    AssetTypeFixed
    Manufacturersales@althon.co.uk
    ModelNumberH8CA
    WarrantyGuarantorPartssales@althon.co.uk
    WarrantyDurationPartsn/a
    WarrantyGuarantorLaborn/a
    WarrantyDurationLaborn/a
    WarrantyDurationUnityear
    ReplacementCostn/a
    ExpectedLife>100
    DurationUnityear
    WarrantyDescriptionn/a
    NominalLength1370
    NominalWidth685
    NominalHeight1150
    ModelReferencePrecast Concrete Headwall
    Shapen/a
    Size1370 x 685 x 1150
    ColourLight Grey
    FinishSteel mould concrete finish
    Graden/a
    MaterialConcrete
    Constituentsn/a
    FeaturesLifting points cast into headwall
    AccessibilityPerformancen/a
    CodePerformanceBS EN 15258:2008
    SustainabilityPerformancen/a

    Althon_General Parameters

    Parameter Name Parameter Value
    AuthorAlthon Limited
    BIMObjectNameAlthonLimited_PrecastConcreteHeadwall_H8CA_375mmIDPipe_100mmIL
    Version1
    LastUpdated2019-04-17T09:17:00
    ADSKCompatible2X3
    RevitCompatible2018 +
    ManufactureNameAlthon Limited
    ManufacturerURLwww.althon.co.uk
    NBSDescriptionPrecast concrete headwall unit
    NBSNoten/a
    NBSOfficeMasterTagn/a
    NBSReference45-25-40/305
    NBSTypeIDn/a
    DocumentationLiteraturehttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationInstallationGuidehttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationTechnicalhttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationCertificatesOn request
    Uniclass2015codePr_20_93_37_65
    Uniclass2015TitlePrecast concrete headwall units
    Uniclass2015VersionProducts v1.13
    AlthonGeneralNotesWe can cast multiple pipe opening, elliptical, square or rectangular culvert openings into any of our headwalls. We can also cast pipe openings into the wing walls of our headwalls.
    AlthonHeadwallInstallationUnits should be bedded on minimum 150mm of semi-dry concrete. Sit the headwall level or with a slight fall 1:50 from pipe to spill mouth.
    AlthonHandlingA. Weight of concrete is based on 2.4 tonne/m³+5% is recommended for sizing lifting equipment B. All lifting points shall be used as specified below - Anchor points & loops - Total Qty 3 C. Unit to be lifted as per lifting diagram
    AlthonConcreteA. Mix ref: Self-compacting DC4/DS4 Mix B. Lifting strength bases on 2 cubes = 20N/mm² C. Characteristic 28 day cube strength = 50N/mm² D. Concrete provides Design Chemical Class 4 (DC4) to special Digest1, Table F2
    AlthonReinforcementA. Reinforcement to BS EN 13369 B. Scheduling, dimensioning, bending & cutting to BS8666 C. Cage to be machine tied with steel wire
    AlthonManufactureA. Manufacture to BS EN 15258:2008 precast concrete products - Retaining wall elements, Factory Production Control certificate number: 0086-CPR-650448 & BS EN 13369 B. Tolerances to BS EN 13369 clause 4.3.1.1 C. Finishing Top: Class A Sides: Class A Base: Class A Rear of back wall: Self-Levelled D. Marking: Units shall be indelibly marked to show: mould reference code De-mould date Job reference number and unique product number unit weight (kg)
    AlthonDesignA. Concrete design to EC2 B. Althon have designed the concrete units only, the site conditions should be assessed for suitability by the scheme designer C. Units are designed to withstand a vertical live load surcharge of 10kN/M² D. Weight of soil - 18kN/M² E. Angle of internal friction = 30 Deg. F. Design Life: >100 years Cover Block Size (mm): All Faces 55 Min Cover Size (mm): All Faces 55 Max Cover Size (mm): All Faces 60 Exposure induced by Carbonation: All Faces XC3/4 Corrosion induced by Chloride: XD3 Freeze/thaw attack: XF4 Chemical attack: XA3
    AlthonFabricationA. Manufacture IAW EN 1090-2 EXC CLASS 1 B. Material grade is to be: BS EN 10025 S275 C. Welding carried out IAW EN 1090-2 PARA 7.5.4 - 7.5.18 D. All fillet and butt welds to have a minimum throat thickness of 6mm & joints to be fully welded where possible. E. Ensure vertical flats are fully welded both sides where possible. F. All sharp edges and burrs are to be removed. G. Remove all weld splatter. H. Holes by punching are permitted with reaming. I. Galvanising is carried out after fabrication to BS EN:ISO 1461
    AlthonSpecificationInformationOpening in back wall cast to suit outside diameter of the pipe work. Invert level of pipe can be set to your specification
    AlthonHeadwallMaxPipeSizeMax Pipe Opening PCC = 450mm ID and Max Pipe Opening Pastic/Clayware = 600mm ID

    Built with: Autodesk Inventor Professional 2018

    H8C A Headwall - 450mm ID pipe - 100mm Invert Level

    Example Render

    H8C A Headwall - 450mm ID pipe - 100mm Invert Level render

    RFA Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download RFA Object

    ADSK Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download ADSK Object

    IFC Object

    Version: 1
    Last Updated: April 17, 2019, 9:17 a.m.

    Download IFC Object

    COBie Parameters

    Parameter Name Parameter Value
    NamePrecastConcreteHeadwall_H8CA_450mmIDPipe_100mmIL_AlthonLimited
    CreatedBydrawings@althon.co.uk
    CreatedOn2019-04-17T09:17:00
    Categoryn/a
    DescriptionPrecast Concrete Headwall
    AssetTypeFixed
    Manufacturersales@althon.co.uk
    ModelNumberH8CA
    WarrantyGuarantorPartssales@althon.co.uk
    WarrantyDurationPartsn/a
    WarrantyGuarantorLaborn/a
    WarrantyDurationLaborn/a
    WarrantyDurationUnityear
    ReplacementCostn/a
    ExpectedLife>100
    DurationUnityear
    WarrantyDescriptionn/a
    NominalLength1370
    NominalWidth685
    NominalHeight1150
    ModelReferencePrecast Concrete Headwall
    Shapen/a
    Size1370 x 685 x 1150
    ColourLight Grey
    FinishSteel mould concrete finish
    Graden/a
    MaterialConcrete
    Constituentsn/a
    FeaturesLifting points cast into headwall
    AccessibilityPerformancen/a
    CodePerformanceBS EN 15258:2008
    SustainabilityPerformancen/a

    Althon_General Parameters

    Parameter Name Parameter Value
    AuthorAlthon Limited
    BIMObjectNameAlthonLimited_PrecastConcreteHeadwall_H8CA_450mmIDPipe_100mmIL
    Version1
    LastUpdated2019-04-17T09:17:00
    ADSKCompatible2X3
    RevitCompatible2018 +
    ManufactureNameAlthon Limited
    ManufacturerURLwww.althon.co.uk
    NBSDescriptionPrecast concrete headwall unit
    NBSNoten/a
    NBSOfficeMasterTagn/a
    NBSReference45-25-40/305
    NBSTypeIDn/a
    DocumentationLiteraturehttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationInstallationGuidehttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationTechnicalhttps://www.althon.co.uk/products/h8c-headwall/detail/
    DocumentationCertificatesOn request
    Uniclass2015codePr_20_93_37_65
    Uniclass2015TitlePrecast concrete headwall units
    Uniclass2015VersionProducts v1.13
    AlthonGeneralNotesWe can cast multiple pipe opening, elliptical, square or rectangular culvert openings into any of our headwalls. We can also cast pipe openings into the wing walls of our headwalls.
    AlthonHeadwallInstallationUnits should be bedded on minimum 150mm of semi-dry concrete. Sit the headwall level or with a slight fall 1:50 from pipe to spill mouth.
    AlthonHandlingA. Weight of concrete is based on 2.4 tonne/m³+5% is recommended for sizing lifting equipment B. All lifting points shall be used as specified below - Anchor points & loops - Total Qty 3 C. Unit to be lifted as per lifting diagram
    AlthonConcreteA. Mix ref: Self-compacting DC4/DS4 Mix B. Lifting strength bases on 2 cubes = 20N/mm² C. Characteristic 28 day cube strength = 50N/mm² D. Concrete provides Design Chemical Class 4 (DC4) to special Digest1, Table F2
    AlthonReinforcementA. Reinforcement to BS EN 13369 B. Scheduling, dimensioning, bending & cutting to BS8666 C. Cage to be machine tied with steel wire
    AlthonManufactureA. Manufacture to BS EN 15258:2008 precast concrete products - Retaining wall elements, Factory Production Control certificate number: 0086-CPR-650448 & BS EN 13369 B. Tolerances to BS EN 13369 clause 4.3.1.1 C. Finishing Top: Class A Sides: Class A Base: Class A Rear of back wall: Self-Levelled D. Marking: Units shall be indelibly marked to show: mould reference code De-mould date Job reference number and unique product number unit weight (kg)
    AlthonDesignA. Concrete design to EC2 B. Althon have designed the concrete units only, the site conditions should be assessed for suitability by the scheme designer C. Units are designed to withstand a vertical live load surcharge of 10kN/M² D. Weight of soil - 18kN/M² E. Angle of internal friction = 30 Deg. F. Design Life: >100 years Cover Block Size (mm): All Faces 55 Min Cover Size (mm): All Faces 55 Max Cover Size (mm): All Faces 60 Exposure induced by Carbonation: All Faces XC3/4 Corrosion induced by Chloride: XD3 Freeze/thaw attack: XF4 Chemical attack: XA3
    AlthonFabricationA. Manufacture IAW EN 1090-2 EXC CLASS 1 B. Material grade is to be: BS EN 10025 S275 C. Welding carried out IAW EN 1090-2 PARA 7.5.4 - 7.5.18 D. All fillet and butt welds to have a minimum throat thickness of 6mm & joints to be fully welded where possible. E. Ensure vertical flats are fully welded both sides where possible. F. All sharp edges and burrs are to be removed. G. Remove all weld splatter. H. Holes by punching are permitted with reaming. I. Galvanising is carried out after fabrication to BS EN:ISO 1461
    AlthonSpecificationInformationOpening in back wall cast to suit outside diameter of the pipe work. Invert level of pipe can be set to your specification
    AlthonHeadwallMaxPipeSizeMax Pipe Opening PCC = 450mm ID and Max Pipe Opening Pastic/Clayware = 600mm ID

    Built with: Autodesk Inventor Professional 2018

    Brochures, Datasheets and Installation Instructions for H8C A Headwall

    Free headwall design service

    If you cannot find what you are looking for our Free Headwall Design Service can help.

    More information